CLINICAL CHEMISTRY ANALYSER (AUTOLYSER)


MODELS:

  • Autolyser Modell 20010A
without 4-steps washing station and without cooled reagent tray

  • Autolyser Modell 20010D
with 4-steps washing station and cooled reagent tray


TECHNICAL SPECIFICATIONS

Sampling and reagent center:

  • Samples:
48 positions sample carrousel
Primary tubes with barcode option
Accepts pediatric micro-samples
Sample volume: programmable 2-100µl

  • Reagents:
48 cooled positions reagent caroussel
Reagent volume: programmable:
Reagent 1: from 0 to 1600µl
Reagent 2: from 0 to 1600µl
Typical reagent volume: 350µl

Pipetting system:
  • Reagent probe heater
  • Capacitive liquid level sensor
  • Washing system outside and inside the probe

Reaction tray:
  • 80 positions reaction tray with washing station
  • 4 steps washing station
  • Water consumption: 1 liter / 500 tests
  • Warmed air incubator: ambient, 30°C and 37°C

Optic system
  • Double beam
  • Interference filters: 340, 405, 450, 505, 550, 590, 650, 700 and 750nm
  • Bandwidth: 10nm
  • Photometric range: -0.1 to 3.6A
  • Light source: halogen lamp 6V-20W

Analysis modes:
  • End point with sample blank or reagent blank
  • Use of factor or standard
  • Priority selection by sample (profile) or by reagent (blank)
  • Use of calibration curve with up to 10 standards
  • Automatic curve fit
  • Coagulation times by turbidimetry
  • Fast and two-point kinetics (zero and first order)
  • Routine, batch, STAT procedures, profiles
  • Automatic analysis redilution on abnormal levels,
  • excessive substrate
  • consumption and / or lack of linearity
  • Full quality control: Levy-Jennings plots, Westgard rules
  • Import / export of data, methods and historic file
  • Automatic backup procedure

Throughput:
  • Up to 230 tests / hour depending on configuration

Power requirements:
  • 110/230 VAC; 50/60 Hz; 100VA

Data management:
  • Computer: PentiumTM or last state of the art computer
  • Color SVAG monitor
  • Multitasking Windows software, Mouse
  • 3.5 1/2” disk drive and CD-Rom drive
  • Printer: 80 columns.
  • Interface: bi-directional RC 232C

Dimensions / Weight
  • 85 x 58 x 47 cm, 40 kg