PHOTOMETER DTN-410K



NEW FEATURES:

Innovation relies on the fact that a PC Keyboard can be included, incorporating the advantage of creating a worklist indicating the patient’s name, sex, age and all methods to be measured. Once measurements are performed in batch per method, each patient’s report is printed.
By using a full PC Keyboard, it eases input of patient’s data.

Other important advantages:

  • Real time reaction curve display
  • Big memory. Up to 2000 results.
  • Languages: English, Spanish, Chinese, Portuguese
  • Price: on request

Keyboard is not included: any English or Spanish PC Keyboard is compatible.
All advantages of the DTN-410 remain.


SPECIFICATIONS:

LIGHT SOURCE
  • Quartz-halogen lamp 6V- 10W

PHOTOMETRIC RANGE
  • -0.5 to 4,000 Absorbance

DETECTOR
  • Photo diode (320-1000 nm).

WAVELENGTH RANGE
  • Automatic 9 positions filter wheel;
  • Seven standard interference filters: 340, 405, 450, 505, 550, 620 and 750 nm.
  • Three positions for optional filters.

BLANKING
  • Automatic zero setting
  • Water blanking
  • Reagent blanking

DUAL CUVETTE SYSTEM
  • 18 µl metal flowcell with quartz windows.
  • Standard 10x10 mm holder for macro or semi-macro cuvettes.

TEMPERATURE CONTROL
  • Peltier elements system.
  • Temperature setting between 25ºC and 37ºC.

METHODS IN MEMORY
  • 132 methods in memory, protected with built-in, nonserviceable, battery.

MEASUREMENT PROCEDURES
  • Kinetics, with linearity check;
  • Kinetic, with linearity check and blanking.
  • Two points, with or without reagent blank;
  • End point monochromatic or bichromatic, with or without reagent blank;
  • Coagulation.

MEASURING TIME
  • Programmable, 2 to 600 seconds for kinetic and two point type of tests;
  • For end point variable from 1 to 600 seconds.

DELAY TIME
  • Programmable, 0 to 600 seconds.

METHOD PARAMETER SETTINGS
  • Method name.
  • Measurement mode;
  • Wavelength 1 and 2;
  • Aspiration volume;
  • Measurement delay;
  • Measurement time;
  • Factor;
  • Concentration of standards;
  • Reagent blank y/n;
  • Sample blank y/n;
  • Units for results;
  • Levels for flagging;
  • Curve fit y/n;
  • Linearity check

CALIBRATION
  • Factor, one-point, twopoint and multi-point;
  • Automatic on 1 standard (linear mode);
  • Automatic for up to 10 standards (non linear mode).

QUALITY CONTROL
  • Four controls per test;
  • QC survey of last 10 control measurements;
  • Levey Jenning plot;
  • High/low flags.

ASPIRATOR SYSTEM
  • Built-in peristaltic pump driven by stepper motor; programmable; reversible for sample recovery.
  • Reaction volume: variable 100 to 1000 µl per test.
  • Carryover < 2 % for sipping volume >400 µl

OPERATOR INTERFACE
  • Membrane keyboard with 25 buttons for functions and numeric centries
  • Graphic LCD display 20 x40 characters with backlight

PRINTER
  • Thermal, graphic 24 characters per line.

SIGNAL INTERFACE
  • RS 232 type serial port;
  • PS 2 type port for external keyboard.
  • Serial to USB host

QUALITY
  • CE
  • ANMAT
  • ISO 9001

LANGUAGES
  • English
  • Spanish
  • Chinese
  • Portuguese
  • Other languages on request.

POWER REQUIREMENTS
  • 100-240 VAC 50/60 Hz;
  • Ground connection
  • 150 W

DIMENSIONS
  • W x H x D: 32 x 17 x 38 cm

WEIGHT
  • 6 Kg.

OPTIONALS
  • PC keyboard