PHOTOMETER DTN-410K
NEW FEATURES:
Innovation relies on the fact that a
PC Keyboard can be included, incorporating the advantage of creating a
worklist indicating the patient’s name, sex, age and all methods to be
measured. Once measurements are performed in batch per method, each
patient’s report is printed. By using a full PC Keyboard, it eases
input of patient’s data.
Other important advantages:
- Real time reaction curve display
- Big memory. Up to 2000 results.
- Languages: English, Spanish, Chinese, Portuguese
- Price: on request
Keyboard is not included: any English
or Spanish PC Keyboard is compatible. All advantages of the DTN-410
remain.
SPECIFICATIONS:
LIGHT SOURCE
- Quartz-halogen lamp 6V- 10W
PHOTOMETRIC
RANGE
DETECTOR
- Photo diode (320-1000 nm).
WAVELENGTH
RANGE
- Automatic 9 positions filter wheel;
- Seven standard interference filters: 340, 405, 450, 505, 550, 620 and 750
nm.
- Three positions for optional filters.
BLANKING
- Automatic zero setting
- Water blanking
- Reagent blanking
DUAL CUVETTE SYSTEM
- 18 µl metal flowcell with quartz windows.
- Standard 10x10 mm holder for macro or semi-macro cuvettes.
TEMPERATURE CONTROL
- Peltier elements system.
- Temperature setting between 25ºC and 37ºC.
METHODS IN MEMORY
- 132 methods in memory, protected with built-in, nonserviceable, battery.
MEASUREMENT PROCEDURES
- Kinetics, with linearity check;
- Kinetic, with linearity check and blanking.
- Two points, with or without reagent blank;
- End point monochromatic or bichromatic, with or without reagent blank;
- Coagulation.
MEASURING TIME
- Programmable, 2 to 600 seconds for kinetic and two point type of tests;
- For end point variable from 1 to 600 seconds.
DELAY
TIME
- Programmable, 0 to 600 seconds.
METHOD PARAMETER
SETTINGS
- Method name.
- Measurement mode;
- Wavelength 1 and 2;
- Aspiration volume;
- Measurement delay;
- Measurement time;
- Factor;
- Concentration of standards;
- Reagent blank y/n;
- Sample blank y/n;
- Units for results;
- Levels for flagging;
- Curve fit y/n;
- Linearity check
CALIBRATION
- Factor, one-point, twopoint and multi-point;
- Automatic on 1 standard (linear mode);
- Automatic for up to 10 standards (non linear mode).
QUALITY CONTROL
- Four controls per test;
- QC survey of last 10 control measurements;
- Levey Jenning plot;
- High/low flags.
ASPIRATOR SYSTEM
- Built-in peristaltic pump driven by stepper motor; programmable; reversible
for sample recovery.
- Reaction volume: variable 100 to 1000 µl per test.
- Carryover < 2 % for sipping volume >400 µl
OPERATOR INTERFACE
- Membrane keyboard with 25 buttons for functions and numeric centries
- Graphic LCD display 20 x40 characters with backlight
PRINTER
- Thermal, graphic 24 characters per line.
SIGNAL
INTERFACE
- RS 232 type serial port;
- PS 2 type port for external keyboard.
- Serial to USB host
QUALITY
LANGUAGES
- English
- Spanish
- Chinese
- Portuguese
- Other languages on request.
POWER
REQUIREMENTS
- 100-240 VAC 50/60 Hz;
- Ground connection
- 150 W
DIMENSIONS
- W x H x D: 32 x 17 x 38 cm
WEIGHT
OPTIONALS
|