Instruments > Photometer DTN405
 

PHOTOMETER DTN-405



FEATURES:

  • Easy keypad operation with LCD display
  • Wavelengths from 330 – 800 nm
  • 5 standard filters (340, 405, 505, 546, 578 nm)
  • 3 more filters optional
  • Reagent-open system supports flowcell and cuvette mode
  • Analytical modes include kinetic, two point, bichromatic with or without reagent blank or sample blank, linear or non-linear calibration curves
  • Memory for 47 programs and 2000 test results
  • Excellent QC function, 2 controls per test
  • Internal thermal-sensitive printer
  • Compact design enables USER-DIY maintenance
  • Standard English or other languages software on request




OPTICAL SYSTEM:

  • Monochromator with interferential filters
  • Wavelength selection: automatic 8 positions filter wheel, 5 installed filters, 3 empty positions
  • Filter wheel (automatic): 340, 405, 505, 546 and 578
  • Light source: Halogen lamp
  • Absorption Range: -0.5 to 3.000 Abs
  • Wavelength Range: from 340 nm to 800 nm
  • Bandwidth: <8 nm
  • Resolution: 0.001 Abs
  • Zero: Automatic
  • Reading: monochromatic and bichromatic



PROGRAMS:

  • 47 open tests
  • Printer control
  • Variable aspiration rate and sample recovery
  • Automatic calibration and test mode
  • Quality control



CUVETTE SYSTEM:

  • Two-way cuvette system: Metallic microflow cell: 32 µl - 10 mm light path with temperature control by Peltier system. Temperature: variable, pre-adjusted 25 °C, 30°C and 37 °C. Stability +/- 0.1 °C.Standard 10 mm x 10 mm cuvette holder for macro or semi-micro cuvettes. Useful for coagulation tests and special methods



ASPIRATION SYSTEM:

  • Built-in peristaltic pump driven by stepper motor, programmable, reversible for sample recovery
  • Reaction volume: variable 200 to 2000 µl per test
  • Carryover: < 1.5 % for sipping volume of 300 µl



PRINTER:

  • internal Thermal graphic printer



OPERATOR'S INTERFACE:

  • Membrane keyboard with 20 keys for functions and numeric entries for very simple and fast action handling



DATA PRESENTATION:

  • Graphic LCD display 240 x 64 characters with backlight
  • Display of sample number, absorbance, concentration, standard, factor, limits
  • Automatic result printouts



ELECTRICAL DATA

Interface: RS232C
Power requirements: 110/230 VAC, 50/60 Hz, 50 VA